From : gixxer05
Q: i have a trouble code that says that the generator field no switching proderly. the manual says to check the generatorfield control circuit. does any one know what this means and how i can fix it .
Replies:
From : tbone
im not sure. my crystal ball is getting fuzzy and is not giving me a clear picture as to the make model or year of the vehicle in question. perhaps you could help me out. -- if at first you dont succeed youre not cut out for skydiving i have a trouble code that says that the generator field no switching proderly. the manual says to check the generatorfield control circuit. does any one know what this means and how i can fix it .
From : Annonymous
gixxer05 wrote i have a trouble code that says that the generator field no switching proderly. the manual says to check the generatorfield control circuit. does any one know what this means and how i can fix it pcm is unable to regulate generator field current. check for 12 volts to alternator field. check for open field in alternator; connections brushes alternator field winding continuity. check wiring between alternator field and pcm. possible bad pcm. .